G60
No. of Syringes:1
Flow rates:0.0025-1250 mL/min
Display:-
Control:RS485 or RS232
Stroke of the drive unit:A total of 6,000 steps
Motor:
- Product Parameters
- Selection Guide
- Service Guarantee
- Related Products
-
Technical Specifications
Accuracy ≤1.0 % (syringe ≥1 mL) Precision CV≤0.05% at full stroke (with syringe ≥ 500 uL ) Wetted material Borosilicate glass,PTFE,PFA,CTFE,ETFE,UHMW-PE Dimension (L x W x H) 143.5mm*65mm*254mm Weight 2.15 kg Power supply DC 24V,1.5A (peak) Syringe and Drive
Syringe fitting 1/4″-28 thread Syringe 50uL, 100uL, 250uL, 500uL, 1mL, 2.5mL, 5mL, 10mL, 25mL Syringe material Borosilicate glass,stainless steel plunger with PTFE coating, PTFE or UHMW-PE plunger tip Resolution (standard mode) 6000 steps with 0.01mm in 1 step Resolution (microstep mode) 48000 microsteps with 1.25um in 1 microstep Travel 60mm Time for full stroke 1.26s-1200s Drive system Ball screw drive Valve & Valve Drive
Turn Time ≤250ms between adjacent ports Valve options Standard: 3-port valve; optional: 3-port distribution valve, 4-port valve, T-valve, through valve or valve free Max pressure 0.68MPA Fitting 1/4″-28 thread Communication
Interface RS485, RS232, external control input and output Protocol Data terminal,OEM protocol (serial) Baud rate 9600bps or 38400bps Format Data bit: 8; parity: none; stop bit: 1; half duplex (RS232/485) Firmware
Topology group Up to 15 pumps in one group, support group control and individually addressed Homing Algorithm Plunger home position is identified by motor stall, which will reduce the dead volume of the system Halt function "h " command is used to halt execution of the command string during plunger movement. To resume execution with "R" or "r" command Microstep mode Set microstep mode for smoother motion with 48000 microsteps per stroke, 1/8 microstepping or 1/16 microstepping Programmable parameter Programmable ramps, cut-off velocity, plunger speeds, backlash compensation,programmable work-flow command set , delays and loops, terminate moves, diagnostics, absolute and relative positions Environmental
Operating temperature Recommended: 15℃-40℃ ,use low temperature syringe for low temperature application Operating Humidity <80% RH, no condensation Storage temperature -20℃-65℃ Storage Humidity <80% RH, no condensation
-
Selection Strategy1. Confirm the required flow rate (mL/min) and the number of pipelines to be conveyed.
2. Confirm the usage scenario – it can be used directly or in conjunction with equipment, controlled via RS485 or external signals.
3. Parameter display – digital tubes only show speed; LCD screens display flow rate, speed, and other calibration parameters; touch screens display flow rate, speed, and other programming or configuration parameters.
4. Liquid composition – affects the choice of tubing. For conventional fluids, platinum-cured silicone tubing is recommended; for corrosive fluids, imported tubing is recommended.
Considerations when selecting a driver:
- Flow rate – the higher the driver speed, the greater the flow; select an appropriate driver based on the reference flow rate.
- Control method – options include fixed speed, adjustable speed, adjustable speed with flow correction (for precise flow control), adjustable speed with flow distribution (quantitative distribution), and external signal control, among others.
- Parameter display – choices include digital tubes, LCD screens, and touch screens.
- Protection – depending on the usage environment, consider the sealing, dust-proof, and waterproof requirements for the driver.
Considerations when selecting a pump head:
- Flow rate – select an appropriate pump head according to the reference flow rate.
- Tubing replacement frequency – except for OEM series products, most pump heads meet the requirements for quick tubing replacement.
- Suitable number of channels – for multi-channel requirements, you can choose a multi-channel pump head or connect pump heads in series.
- Chemical resistance – consider the impact of fluid overflow on pump head materials.
Considerations when selecting tubing:
- Flow rate – refer to the tubing’s reference flow rate curve.
- Chemical resistance – select the material of the tubing accordingly.
- Fluid temperature – different materials perform differently at various temperatures.
- Suction requirements – high-performance tubing should be selected if suction requirements exist.
- Tubing lifespan – the lifespan varies depending on usage conditions; for example, BPT tubing is nearly 30 times more durable than domestic silicone tubing.
-
Regarding Delivery TimePeristaltic pumps, syringe pumps, micro plunger pumps, domestically produced silicone tubing, and other series of products are mostly in stock and can be shipped within 48 hours;
Filling machines, filling systems, and other products are usually made to order, with relatively low inventory. The delivery time is about 1–2 weeks, with a small portion in stock;
Common models of imported hose series products are stocked; due to the impact of international logistics on imported hoses, under special circumstances, the delivery time is about 1–4 weeks;
Note: All peristaltic pump series products require 3 days of continuous operation and aging before leaving the factory to ensure a lower failure rate and allow customers to use them with confidence.
Regarding After-Sales
Warranty is one year (excluding consumables; improper use or human damage is not covered)
For special situations caused by selection or actual application, such as flow differences, usage environment, or personal reasons, products can be directly exchanged by contacting customer service, as long as it does not affect secondary sales.
Regarding Logistics
Please communicate with customer service and confirm.