Peristaltic Pump Flow Calculation Method

2023-03-22 10:07:44

Peristaltic pumps are positive displacement pumps, and the flow output generated per revolution is fixed. By adjusting the rotation speed, the required flow can be easily obtained.

Therefore, by testing the flow at a fixed speed of the peristaltic pump, the output flow at different speeds can be calculated. Typically, the calculated flow and the actual flow have an error range within 2%.

Calculation Method

1. Confirm the detailed configuration of the peristaltic pump, including the driver, pump head, and tubing model.

2. Obtain the flow at the current configuration and fixed speed, using 1 minute as the reference.

3. Flow ÷ Speed gives the flow output per revolution for the current configuration.

4. Adjust the required flow according to the flow output per revolution.

Note

Flow-type peristaltic pumps and distribution-type peristaltic pumps, with flow display and calibration functions, can directly adjust the flow size.
 

Product Recommendation >

  • GXA100/WX10 - T10

    Technical Specifications Channels 10; The master controller can control up to 32 channels, which can be set with individual parameters

    View Details
    GXA100/WX10 - T10
  • Viton Pure fluororubber peri

    Black opaque; Masterflex Viton fluoroelastomer tubing, resistant to ozone, weathering, corrosive chemicals, oils, fuels, solvents, and most mineral acids;Opera

    View Details
    Viton Pure fluororubber peri
  • Chemical Lined coating doubl

    TYGON® Chemical peristaltic pump tubing, as a high-performance co-extruded product, uses a special formulation that combines chemical resistance and pump t

    View Details
    Chemical Lined coating doubl
  • A-60-G Industrial-grade peri

    TYGON® A-60-G significantly outperforms neoprene hoses, EPDM hoses, and other general-purpose hoses in repeated testing and applications.Even when exposed

    View Details
    A-60-G Industrial-grade peri